OnixS C++ Euronext Optiq MDG Handler 1.3.3
API documentation
Loading...
Searching...
No Matches
HandlerSettings Struct Reference

Public Member Functions

 HandlerSettings ()
std::string toString () const

Public Attributes

std::string licenseString
std::string licenseDirectory
std::string logDirectory
std::string logFileNamePrefix
LogSettings::Enum logSettings
LogLevel::Enum logLevel
LogFilePermission::Enum logFilePermissions
std::string networkInterface
std::string networkInterfaceA
std::string networkInterfaceB
UInt32 heartbeatInterval
UInt32 outOfOrderPacketMaxInterval
UInt32 lostPacketWaitTime
bool useFeedA
bool useFeedB
FeedDescriptor realtimeMulticastFeed
FeedDescriptor snapshotMulticastFeed
unsigned short maxPacketSize

Detailed Description

Definition at line 112 of file HandlerSettings.h.

Constructor & Destructor Documentation

◆ HandlerSettings()

HandlerSettings ( )
inline

Constructor.

Definition at line 115 of file HandlerSettings.h.

Member Function Documentation

◆ toString()

std::string toString ( ) const
inline

Returns the string representation.

Definition at line 265 of file HandlerSettings.h.

Member Data Documentation

◆ heartbeatInterval

UInt32 heartbeatInterval

Specifies maximal time interval between two network packets.

If no data is received during specified time frame, corresponding warning is raised.

Interval is measured in seconds.

Note
The default value is '3'.

Definition at line 190 of file HandlerSettings.h.

◆ licenseDirectory

std::string licenseDirectory

Path to the license directory.

Definition at line 135 of file HandlerSettings.h.

◆ licenseString

std::string licenseString

License string.

Definition at line 132 of file HandlerSettings.h.

◆ logDirectory

std::string logDirectory

Log files are stored in this directory.

Definition at line 138 of file HandlerSettings.h.

◆ logFileNamePrefix

std::string logFileNamePrefix

Template of log file name without extension.

Definition at line 141 of file HandlerSettings.h.

◆ logFilePermissions

LogFilePermission::Enum logFilePermissions

Log file permissions.

Note
The default value is ReadAll | WriteOwnerOnly

Definition at line 154 of file HandlerSettings.h.

◆ logLevel

LogLevel::Enum logLevel

Log verbosity.

Note
The default value is LogLevel::Info

Definition at line 149 of file HandlerSettings.h.

◆ logSettings

LogSettings::Enum logSettings

Combine LogSettings enum values to configure the logger.

Definition at line 144 of file HandlerSettings.h.

◆ lostPacketWaitTime

UInt32 lostPacketWaitTime

Indicates for how long Handler should wait for the packet before it's considered as totally lost.

Due to unreliable nature of multicast, data transmitted by MDP may come in order other than original or be completely lost. When Handler receives packet with sequence number greater than expected, it considers received data as out-of-order. If for a certain time interval Handler receives missing data, Handler resumes normal data processing. However, if no data is received for predefined time frame, Handler considers missing data as lost and raises packet gap event. Given parameter defines size of time interval Handler waits for missing data.

Note
When out-of-order packet is received, Handler makes a decision on data loss if either waiting time is over or if newly received packet has sequence number greater than 'seqNumberOfLastReceivedPacket + outOfOrderPacketMaxInterval'.
See also
'outOfOrderPacketMaxInterval' parameter for more information.

Time interval is measured in microseconds (uSec).

Note
The default value is '100000' (100 milliseconds).

Definition at line 241 of file HandlerSettings.h.

◆ maxPacketSize

unsigned short maxPacketSize

Max size for network packet transmitted by Euronext Optiq MDG.

Note
The default value is 1400 bytes.

Definition at line 262 of file HandlerSettings.h.

◆ networkInterface

std::string networkInterface

Specifies one or more network interfaces to use while joining the multicast group; use semi-colon delimited list if more than one.

On Linux the network interfaces is specified by its name, on Windows - by IP address.

Note
If the value is empty or absent then the default networking interface is used.

Definition at line 163 of file HandlerSettings.h.

◆ networkInterfaceA

std::string networkInterfaceA

Specifies one or more network interfaces to use while joining the multicast group A; use semi-colon delimited list if more than one.

On Linux the network interfaces is specified by its name, on Windows - by IP address.

Note
If the value is empty or absent then the networkInterface_ filled value is used.

Definition at line 172 of file HandlerSettings.h.

◆ networkInterfaceB

std::string networkInterfaceB

Specifies one or more network interfaces to use while joining the multicast group B; use semi-colon delimited list if more than one.

On Linux the network interfaces is specified by its name, on Windows - by IP address.

Note
If the value is empty or absent then the networkInterface_ filled value is used.

Definition at line 181 of file HandlerSettings.h.

◆ outOfOrderPacketMaxInterval

UInt32 outOfOrderPacketMaxInterval

Defines value of threshold used by Handler to differ out-of-order packets from gaps.

Due to unreliable nature of multicast, packets transmitted by exchange may be received in the order different to original. To differ the case when Handler received out-of-order packets from the case when some of packets were completely lost, Handler uses given parameter. It defines size of interval for incoming packets starting from the last received. Packet is considered as out-of-order if its sequence number fits into interval [seqNumberOfLastReceivedPacket, seqNumberOfLastReceivedPacket + outOfOrderPacketsMaxInterval]. In that case Handler waits for other packets to fulfill the incoming sequence. If received packet has greater sequence number than 'seqNumberOfLastReceivedPacket + outOfOrderPacketsMaxInterval', then Handler makes a decision on packets lost and gap is reported.

Note
When out-of-order packet is received, Handler makes a decision on data loss if either waiting time is over or if newly received packet has sequence number greater than 'seqNumberOfLastReceivedPacket + outOfOrderPacketMaxInterval'.
See also
'lostPacketWaitTime' parameter for more information.
Note
The default value is '3'.

Definition at line 216 of file HandlerSettings.h.

◆ realtimeMulticastFeed

FeedDescriptor realtimeMulticastFeed

Realtime feed.

Definition at line 254 of file HandlerSettings.h.

◆ snapshotMulticastFeed

FeedDescriptor snapshotMulticastFeed

Snapshot feed.

Definition at line 257 of file HandlerSettings.h.

◆ useFeedA

bool useFeedA

Option to use feed A.

Note
The default value is 'true'.

Definition at line 246 of file HandlerSettings.h.

◆ useFeedB

bool useFeedB

Option to use feed B.

Note
The default value is 'true'.

Definition at line 251 of file HandlerSettings.h.